FirePro vs others

Category : Fire Extinguishing Aerosol System

  EFFECT
ON
HUMANS
EFFECT
ON
PROPERTY
EFFECT
ON
ENVIRONMENT
Foam and Water Human protection necessary when used in fixed systems. May be corrosive due to large water concentration
Residue is harmful to delicate electronics
Residue can be difficult
to dispose of and foam
can be poisonous
Water Generally not dangerous to humans when fighting fire Can cause extensive
damage to property
Can release harmful
fumes and substances
on extinguishment
CO2 Highly dangerous to
humans in fire fighting
concentrations.
Cooling effect causes
condensation mist
harmful to electronics
In general more CO2
is released from
other sources
Inert
gases
May lead to inadequate
oxygen supply to the
brain when used alone
No damage caused Naturally occurring
components that do
not pose a threat
Halon Can be used in human
presence but has been
banned.
No damage caused Harmful to the
environment
Can be used in human
presence in designed
concentration and with proper precautions
No damage caused Friendly to environment
It is ozone friendly
It is a Green Product
Various Comparisons Between Agents

Category : Fire Extinguishing Aerosol System

The attempt to take the necessary actions to protect human health and the environment against adverse effects resulting or likely to result from human activities which can modify the ozone layer has led to:

The Montreal Protocol on Substances that Deplete the Ozone Layer as adjusted and/or amended in London 1990 - Copenhagen 1992 - Vienna 1995 - Montreal 1997 - Beijing 1999

Various comparisons between agents
  Halon 1301 Other gas
systems
CO2
Ozone Depletion Potential (O.D.P.) High Low Zero Zero
Global Warming Potential (G.W.P.) Moderate Low Zero Zero
Atmospheric Life-time (A.L.T.) High V.High/Med. V.High Low
Toxicity Low Low High None
Conductivity Low Low Low N/A < 75 Kv
Corrosiveness Moderate Mod/Low Mod/Low None
Volumetric efficiency Good Low Low Good

Extinguishing density (gr/m3)

200-
350gr/m3
350-
950gr/m3
700-
1500gr/m3
from 30-
60+gr/m3

Health problems associated with low concentrations of oxygen in the ambient air, can generally be summarised as:

    * 16% can lead to impaired judgment and breathing
    * 14% can lead to faulty judgement and rapid fatigue
    * 6% can lead to breathing difficulties and be fatal in minutes

It must however be understood that the above conditions are dependent on the length of exposure time.

FP-8

Category : Fire Extinguishing Aerosol System

Gallery - FP-8 Tech Sheet

FP-20

Category : Fire Extinguishing Aerosol System

FP-20 Movie Demonstration

Gallery - FP-20 Tech Sheet

FP-20E

Category : Fire Extinguishing Aerosol System

Gallery - FP-20E Tech Sheet

Gallery - Appli_FP8_FP100_1          Gallery - Appli_FP8_FP100_2

 

FP-80

Category : Fire Extinguishing Aerosol System

Gallery - FP-80 Tech Sheet

FP-80

Category : Fire Extinguishing Aerosol System

Gallery - FP-80 Tech Sheet

 
FP-100

Category : Fire Extinguishing Aerosol System

Gallery - FP-100 Tech Sheet

 
FP-200

Category : Fire Extinguishing Aerosol System

FP-200 Movie Demonstration Link 1

FP-200 Movie Demonstration Link 2

Gallery - FP-200 Tech Sheet

FP-200M

Category : Fire Extinguishing Aerosol System

Gallery - FP-200M Tech Sheet

Gallery - Appli_FP200_FP500_1          Gallery - Appli_FP200_FP500_2

 

FP-500

Category : Fire Extinguishing Aerosol System

Gallery - FP-500 Tech Sheet

FP-1000M

Category : Fire Extinguishing Aerosol System

Gallery - FP-1000M Tech Sheet

FP-1200

Category : Fire Extinguishing Aerosol System

Gallery - FP-1200 Tech Sheet

Gallery - Appli_FP1200          Gallery - Appli_FP1200_2

 

FP-2000

Category : Fire Extinguishing Aerosol System

Gallery - FP-2000 Tech Sheet

Gallery - Appli_FP2000_FP5700_1          Gallery - Appli_FP2000_FP5700_2

 

FP-3000

Category : Fire Extinguishing Aerosol System

Gallery - FP-3000 Tech Sheet

Gallery - Appli_FP2000_FP5700_1          Gallery - Appli_FP2000_FP5700_2

FP-5700

Category : Fire Extinguishing Aerosol System

Gallery - FP-5700 Tech Sheet

 

ICT ROOM 
Gallery - FP5700 @ ICT Room 1 
Gallery - FP5700 @ ICT Room 2 

 

REPEATER ROOM 
Gallery - FP5700 @ Repeater Room 1 
Gallery - FP5700 @ Repeater Room 2 

 

UTILITY ROOM 
Gallery - FP5700 @ Utility Room 1 
Gallery - FP5700 @ Utility Room 2 

 

FirePro Product Information

Category : Fire Extinguishing Aerosol System

.: FirePro® Fire Extinguishing Aerosol Systems :.

Gallery - FirePro Product Range

Our company is a distributor of FirePro® Fire Extinguishing Aerosol System products in Indonesia. Our company also participate in the prevention and mitigation of fire hazard by promoting sales of FirePro® Fire Extinguishing Aerosol System product.

Some aspects that are owned by FirePro® products include the following:

1. USEFULNESS OF FirePro®

FirePro® Fire Extinguishing Aerosol System Product is a tool to extinguish the fire, the content of FirePro® is aerosol material ingredients, it consists of Potassium Nitrate, Potassium Carbonate, Magnesium and Polymer Epoxy Resins. 

    HOW FirePro® GENERATOR UNIT WORKS / ACTIVATION METHOD

Mechanism or the way of FirePro® works is like the following, if thermocord (axis), stung by a fire then materials contained in the aerosol generator unit will discharge or spray fire in a matter of a few seconds a fire can be extinguished. Electrical wires can also be connected to Power Supply 6-36V DC and can also be connected to the fire alarm control panel, which is to control the location of the fire generator units installed.

    TO WATCH FirePro® Product VIDEO DEMO :

Type FP-20 click here

Type FP-200 click here and here

2.  FirePro® ADVANTAGE

  • The ability to effectively extinguish the fire, and not necessarily with expensive products
  • On FirePro® efficiency and effectiveness is greater than other fire system products
  • Installation is more practical and easy
  • Fluid is natural mineral so there is no outlet obstruction
  • No high pressure container
  • Save space and weight
  • No damage to property and electronic devices
 
3.  ENVIRONMENTALLY FRIENDLY / ECO-FRIENDLY

  • Global warming potential = 0
  • No Toxic
  • Atmospheric lifetime
  • Does not leave a spot or does not make rusty
  • No Ozone depletion potential
  • No Ozone depletion

 
4. APPLICATIONS
  • Archives Room
  • Raised Floors Room
  • Suspended Ceilings
  • Planning Room
  • Electrical Sub-stations Room
  • Computer and Data Room
  • UPS Systems Room
  • Electrical Panel
  • Electrical Cabinet
  • Soldering Machines
  • TV Sets, PC Screens
  • Personal Computer
  • Marine Vessel
  • Cars
  • Train & Other vehicle
  • and many more...
 
FirePro® ACTIVATION METHOD
  • Electrical Activation
    Activation that is integrated with Smoke Detector and Heat Detector
  • Thermocord Activation
    Activation with thermocord/axis
  • Manual (Hand-Operated Extinguishing Units)
    Activation by pulling safety pin
 
Design
Gallery - FirePro Canister

Watch Video Demo of FirePro® Unit Design for these type :

FP-100 click here

FP-2000 - FP3000 - FP5700 click here

 

Overview of FirePro® Unit :

  1. Firefighter of the metal containers of various shapes and sizes
  2. Solids, aerosol forming compound SBK
  3. A special system built into each FirePro® container / unit for activation of independent  fire extinguisher
  4. Most types equipped with a mechanism to absorb heat (depending on application)

FirePro® Certificates

Gallery - Sertifikasi_FirePro_1

 Gallery - Sertifikasi_FirePro_2

®products comply with the applicable requirements of the Standard for Inert Gas Clean Agent Extinguishing System Units, UL 2127, in effect as of 14th June 2006

 Gallery - Logo Puslabfor   Gallery - Logo KLH  Gallery - Logo_Pmdm_Kbkrn

 

FirePro Classification
Gallery - FirePro Classification
 
Gallery - FirePro NFPA10 
 
Gallery - FirePro EN2